We offer specialized arrangements in the field of medium and low voltage Motor Control Centre. The items might be fixed or extractable frameworks of different plans, to fulfil the useful and establishment necessities of the customer, in full consistence with worldwide standards and guidelines.
Our MCCs offer a colossal measure of use adaptability while sticking to the most tough industry principles. We can likewise offer VFD and Soft starter frameworks to build machine execution and address ongoing issues for energy investment funds as needed by peaceful accords.
Motor Control Centre
Type: Form IV of separation, IP42
Short circuit rating: Type tested for 50 kA short circuit
Available in fully withdrawable, semi-draw out type & Fixed.
Motor Control Panel
Type: Form 2 b
IP rating: IP 54 to IP 65
Starters: DOL, SD, Soft Starter & VFD (Danfoss)
Short Circuit rating: as per client request.
Enclosure: Sheath Metal, GRP & Stainless Steel.
We offer answers for the stockpile of Unit Control Panels dependent on world driving PLC brands. The PLC frameworks offered can include single and CPU repetitive designs, correspondence cards, I/O and power supply.All frameworks are planned and customized by our designing office and introduced by the creation office, cautiously observing worldwide guidelines and the solicitations of the customer. The Unit Control Panels are intended to build the administrator control through the Human Machine Interface (HMI) gadget.
Unit Control Panel
Type: PLC controlled
IP rating: IP 54 to IP 65
PLC: Siemens, Schneider, AB
Explosion proof: Exd, Exp
Enclosure: Sheath Metal, GRP & Stainless Steel
Because of its specialized aptitude and consistent preparing, DIS Energy can address the issues of the customer for the electrical set-up of a machine or framework utilizing cutting edge innovation.
Establishments are completed dependent on worldwide guidelines, following area standards and customer particulars.
Our offer ranges from the supply of the basic electrical equipment, to ATEX certificate solutions for hazardous environments with risk of explosion.
A typical installation comprises a junction box, Local Pushbutton, Instrument Rack and Gauge Panel, as well as instrument cabling with specific cables or personalized conduit solutions.
Local Push Button Station
Type: With & without Ammeter
IP rating: IP 54 to IP 65
Indication & Pushbutton: as per client request
Explosion proof: Exd, Exp
Enclosure: Sheath Metal, GRP & Stainless Steel
Starter Panel
Type: Form 2 b
IP rating: IP 54 to IP 65
Starters: DOL, SD, Soft Starter & VFD (Danfoss)
Short Circuit rating: as per client request.
Explosion proof: Exd, Exp
Enclosure: Sheath Metal, GRP & Stainless Steel
Junction Boxes
Type: Analogue, Digital
IP rating: available in all ranges
Explosion proof: Exd, Exe, Exp
Enclosure: Sheath Metal, Aluminium, GRP & Stainless Steel
Programmable regulators are at the center of interaction control. DIS Energy has been effectively executing programmable regulators since our organization’s establishing. Truth be told, we are an innovator in the process-control industry, perceived as an approved System Integrator (SI) by all major modern programmable regulator producers.
DIS Energy’s prosperity and acknowledgment as a programmable regulator framework integrator can be ascribed to our long stretches of involvement and our demonstrated venture procedure that incorporates :
The HMI is regularly a graphical interface that shows the current status of a cycle, like engine status, valve status, temperatures, pressures and other framework factors. The job of the Human-Machine Interface is to give administrators, support staff and the board with the devices important to access, control and view the boundaries of an interaction. The Human-Machine Interface might run in scope from a solitary independent administrator board, to multi-plant, customer server establishments with various excess servers and disseminated view hubs on the plant floor.
DIS Energy’s experience with Human-Machine Interface installations includes:
Projects at DIS Energy are successfully designed, built, tested and commissioned by following a rigorous project methodology; for HMI development, key aspects of our methodology include:
The correspondence innovation presented by DIS Energy addresses the most exceptional organization foundation accessible available. For the most part dependent on Ethernet principles, it offers both significant degrees of between operability between hardware inside a framework, and the likelihood to remotely get to the machine or framework to complete distant oversight and support work.To work with correspondence between frameworks, our answers depend on standard correspondence conventions with demonstrated unwavering quality, like MODBUS TCP/IP over Ethernet, OPC UA, PROFINET, ControlNet, and so forth
Each of our frameworks are created as per global norms, cautiously adhering to the constructor’s rules and the necessities of the customer, and customizing practical subtleties while conforming to the need to incorporate low level control frameworks with DCS, MES and ERP conveyed control frameworks.